Now Im getting small air bubbles when the speed is on low. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. When I try to turn on high speed it sounds like its jamming and then the breaker trips. The salt cylinder is clean. Hi Frank, two possible reasons might be nighttime moisture (dew), or small insects, both contacting the circuit, on the timer or connected electrical outlet, and causing a brief short, which can trip the breaker. Have zero skills with pool pump filter motors or basically anything associated. I completely back washed and clean the system two times making sure the filter was put together properly and there were no holes in either the manifold or the filter grids. Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. It could also be just too much moisture on the motor terminals. 3200 ppm is the ideal level. Sounds like you might have enough good parts to put together one good pump! 2. 2 No loss of water level in the pool The new pump then starts to overheat and it shuts off. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. Hi Jim, bummer! Replace with the exact same MFD number capacitor if defective (they can be tested) the capacitor is the battery that starts the motor. Hope that helps! check that everything is tight and aligned. Is there a resource I can look at to help understand the enter system, that is control by the Aqua Logic Power Panel. Using a circuit tester, I determined that the timer and the inline switch has power. I IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard. Hi Wilson, I cant find any info on that error message paused / valve change but it would sound like it thinks that either a filter valve or directional valve is being turned, so it has paused water flow. Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. Hi Chad, when a motor makes no noise at all, I suspect power issues. The actual unit of measurement for DE powder (lol) is a 1 lb coffee can size scoop. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. Heater wont ignite when water temp is above 80 degrees. Same with other sensors. Again, flow rate is good but it doesnt make the change in pressure like it should when switching to sweeper. Just bought a brand-new Hayward pump , starts up in primes great but in about five minutes there was no suction or water flow back to the pool . The pump has been running for 2 days. If you have trouble getting past this, an electrician may be a good call to make. Second thought is are the pipes plumbed into the valve correct? How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. Is there a solution for this problem? Still the same results. Nothing your husband did, hes safe to come out of the doghouse, lol. When I then switch the pump breaker off and then back on again it springs into life (every time). Could that be the voltage then or is there another possibility? Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. No matter what setting I put it in its backwashing the sand into the skimmer. new pump started up fine after primed strated to click on and off. was spinning counter clockwise. Motor was replaced then gfci breaker replaced to Hayward recommended breaker (same breaker I had first time) still tripping on every 4-5 days , 10 days inconstant times but again 99% of the time overnight. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). Everything is Primed and ready to go, soon as I put the vacuumin on the skimmer, the pressure stays for about 30 secs then the pressure and water level drop to next to nothing. Profile, Create a Pool Owner After cleaning the pool the pool pump would just hum and not start. Using a Filter Cleaner can help, there may be some goop and gunk in there, even after just months of operation. Please help. Please help! Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. The best way to attack this is with the mantra the problem lies where the power dies. Today, I came home to find my pump off after leaving it on this morning. Hi Curt, not especially uncommon, small stress cracks on the outlet port of the pump, about 1/4 long? Thank you so much, Hi Stephen, could be a loose wire, not just the power wires, but other wires inside the back perhaps, or loose wires on the timeclock or breaker. Have no power at all going to my control panel. Then timer 2 comes on at 3:30 at 2250 rpms, but recently (last 3 mornings) when the second timer at the higher rpms comes on it does not prime and just runs without circulation water through the system. Do you believe I have a bad breaker? Maybe the breaker is loose on the bar, or perhaps insects shorting it. It DOES turn on. If the backwash line continues to leak, remove the multiport valve lid and inspect the spider gasket for wear or damage in the waste port area. Everything seems to be set up correctly on the filter and motor. Right now I can hear the pump running hard when it is turned on, but pressure gauge shows 0. },
I will be purchasing a replacement pump and have it installed, but I wonder if Id need to just have the breakers tightened in the panel box? Also, if there is a GFCI outlet connected, perhaps it is tripped? If it makes no noise at all, check that the GFCI test button is not tripped, and flip the circuit breaker off and back on. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. The filter caterige is brand new too. Just installed a replacement Super Pump and realized a point that may help others as they install. I just replaced my pump/motor at the start of this swimming season. Could this be true? Or it could be a bad breaker, but usually not. How can I locate and check if a valve is faulty. I would appreciate any kind of trouble shooting and support. the termistor was blown. Check all wires and switches and connections in the back of the motor, look for anything loose or ant infested or broken connections. Indeed, it was the capacitor and as soon as I replaced it ($6) the pump is working like a champ. The motor model # is C48L2N134B1. We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. Find answers to your questions about all Ryan, is the breaker a 15-amp? Thanks, Jim, Jim, they can be sticky sometimes. Could be insects or the copper arms are bent, or something caught up in the works, This is usually directly in the center of the motor a centrifugal switch, steel with side springs, and a triangular shaped switch attached at 6 oclock, but contacting the cent. Also check that no wires are touching any metal, and check for any bare/scraped wires. Trying not to damage impeller. If it still trips the breaker, it may have shorted out the motor windings, and is not repairable. I turned off my pool at the control box for 24 hours as I needed a union replaced at the salt cell. Power is always present at supply input. Maybe the transformer is not functioning properly? When I turn on the pump, it sucks water through but only 2/3 of basket is filled as if a suction leak. Nick, it could be the capacitor, I guess water got on the terminal board, to trip the breaker. 8. check power at the motor, with a multimeter set on 240V+ place test probes on the brass screws or terminals where the two power wires connect. All works good now. gives you instant access to PDF files. Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. It leaks where the seal plate connects to the pump/strainer housing. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
A sticky skimmer weir door can cause water blockage to the skimmer, and give priming problems too. Replaced breaker still nothing. Loose connections or insect infestation on contacts, or loose breaker etc, could also cause a different type of start/stop problem, very rapid. If the shaft is free turning, but the pump does not turn on, check power connections. Work through the chart below if your heater displays the following error codes. Something about level of placement of pump in relation to the water surface. Just put he new motor on and its still not working, sounds like power is being sent to the motor, but nothing. 1. If it does not, keep reading. What am I doing wrong?? Stackable Rose Gold Wedding Bands, Spillover is just the spa filling up, and overflowing into the pool, a waterfall feature is something different, with dedicated plumbing and a booster pump usually. There should be no elbow after the flow switch. If power is reaching the motor, but nothing (no noise), look for any disconnected or severed wires in the back (shut off power first), if nothing, the motor may be dead. Air leaks are another source of priming issues. I have backwashed the filter and the water is clear. Do we need a new pump or can the electrical cord be replaced? Your thoughts? Upon restart, pump sounds horrible, like pumping rocks. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Thanks! Any ideas as to what could be the problem? When tablets are used in the skimmers, Flex pipe beneath the skimmer can swell inside and begin to crimp and close (over many years time), so that a small amount of debris can clog the line. If the switch does not close after the blower starts the control will go into lockout with the blower running. For plug-in pumps, be sure the TEST button is not tripped on GFCI outlets, and that the cord is not damaged. You may need to start shopping for a new motor and shaft seal, or a whole new pump of the same size and type. I would turn it off and it would hum and eventually start. Checked circuit breakers inside and out and checked to make sure power is getting to pump. If the motor hums, buzzes, or tries to start, but trips the breaker (or not), could be a bound-up shaft, super clogged impeller, bad capacitor, or bad motor. Tool pump out of storage and hooked up as normal. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. We knows its not electrical. I just replaced the flow switch and that solved one problem, but now I'm only able to produce chlorine when the system is on Super Chlorinate. Just replaced a 1.5 hp Hayward super pump with a 1 hp Hayward super pump. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). Hi there. Shut off the valves or plug the skimmer and return, so you can keep the water in the pool while you get it sealed up. ), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. When incoming pipes or valves are clogged, you can get a surge. If the voltage between the orange and black is not 12VAC, you need to replace the rectifier or the board. I cannot locate the model # on either but believe the filter is a c250. Hi Liane, a click coming from a control panel, could be a relay, clicking to send the signal to start the pump, but the signal is lost along the way. Incorrect sizing can cause multiple problems, including low water flow. What do I need to replace the seal plate, the diffuser, the pump housing? Question, if I can determine which return pipe is broke could I just block off that return and bypass it. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. Guess I was wrong. Hi Jamie, definitely want to use 100 lbs of Pool Filter Sand, unless you are using a sand replacement like Zeosand or FilterGlass. I heard like a crank sound, as if somethings stuck between a propeller if there is. I have replaced the Aqua Rite printed circuit board and the T-Cell-9. A bad shaft seal or loose pipe is likely the cause of your leaky pump. 4 New pump 2 years old. Hi Kelly, the first thing that comes to mind when you say pump stuck, is the common occurrence of rust building up between the rotor and stator, inside the motor. Hi, we had very heavy rain the other night and Im quite sure the rain at least briefly submerged the Hayward 2300 Variable speed pump I have. You should get it back same day or next day, in most cases. Hello, Hi Jeanna, most of those slide from 230 to 115, but some do have to be unplugged and replugged. Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. Capacitor is a battery in the back of the motor, at 9 oclock that assists in starting the motor, if the capacitor was weak, that may draw more amps from the breaker. New gauge was ordered. If youre correct that theres a problem with the internal bypass, what should I do? "url": "https://blog.intheswim.com/"
Hi Tracy, the C48 number is not the pump model, but the motor number. The hub was leaking and had to be replaced. Has been running great. Gas pressure is ok. Any ideas? Not the 12VAC that it says should be there. You can get locally at an electric motor repair shop. Did you figure this out. So I inspected the wiring into the electrical panel. If any of these readings are outside limits, replace motor. Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. Is that a reason to replace impeller? Tighten the fitting hand tight, plus 1/2 turn or so, until really snug, but not super-tight. If valve is open when it should be closed the heater will shut down and go into lockout. Directions say to hold motor end of shaft with wrench and to turn impeller counterclockwise (by hand). Some controllers have a Service Mode button you push, to be able to turn off equipment at the equipment pad, as opposed to an in-house remote panel. All Rights Reserved. Seems impeller is not turning, does it turn both ways or one way? Ive done the reset and it still showing 4300. When you start the pump on low, on the panel it does say load 2 and load 3, "on". What should i do now? On the Swim Pro filters, check the two lock nuts under the lid, which secure the pressure gauge and air assembly, and be sure the filter is seated firmly into the base. Hayward North Star replaces capacitors Twice in a span of 3 month now pool pump not making any noise wondering if I can replace capacitor a third time. I noticed through the basket lid before pump that there was a stream of water(full stream) but to me it didnt seem like enough water being pulled in. If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. The early revisions dont work with the TCELL5 or TCELL9. I was able to isolate all the other electrical circuits at the Aqua Logic power panel. Does this seem odd or excessive? ]), it should cleanly separate the two copper tabs of the stationary switch. I am very sure the water comes from underneath, not from plumbing fitting threads. Thanks for your time! Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. My Hayward xstream filter pump is not turning on at all. MY PUMP STARTS TO PRIME THEN LOSES IT. 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted Hi Rod, if the pump motor was submerged, then it is D.O.A. I believe I checked everything and hoping its just the electric cord and the fact that it is corroded and loose and likely loosing electric current after it gets heated up a bit. Also check that wires are tightly attached, at breaker, timer and pump. "address": "",
It looks simple to replace, but I cant even get the old one off the ground! Step 3: When the instant salt level is stable (and the negative sign still present), cycle slide switch to 'Super Chlorinate' and back to 'Auto'. Is the motor set to accept 220V, and matching what you measure at the motor terminals? Damaged or inadequate wiring, resulting in a power drop, are likely to blame for your Hayward pool pump shutting off. Try to spin the impeller with your fingers, or turn the motor shaft to check that it spins freely, or if not, put a wrench on the shaft and break the rust free. There may also be air leaks on your pump, particularly the pipe or valve that is threaded into the pump, must be sealed with thread sealant tightly. "height": "219",
We also a sense and dispense for pool chemistry that sometimes has a ph feeder timeout error code.could this have something to do with the pool pump running off the scheduled time? Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. My Hayward pump II LX 1.5 horsepower. Wire size inside socket too small (cant carry the current). Now when we try to turn everything on the pump wont start at all and keeps tripping the breaker. Now if none of that advice helps, and you still cannot get the lid to go on, or seal up, I would suspect that either the lid or the housing is warped from an overheating situation, running for long periods of time without water flowing through it. Pumps normal pressure and pulls enough volume to keep bakery full. In such case, filter pressure is lower than normal, if the impeller is clogged. Find these plugs and remove them by loosening the wingnut and wiggling it out. Hopefully it has a switch inside the pump so I can change it for 115. Thank you I have taken the thing apart several times and cleaned those fingers but that wasnt the problem this timeI took a chance and tried the vacuum to see if any debris actually made it to the filter basket and nothing went throughso got a plunger and forced the water through with that and then the pump finally primed!! Try adding another inch of water. Hi Amy, the timer is usually wired between the pump and the breaker. Yes, pool heaters do have a minimum flow requirement. If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. I have it set on a timer and when the pump comes on the flow rate is good but as the day goes on it becomes less and less. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. My hayward powerflo matrix 1.5hp pump doesnt turn on after working fine the whole month of June. I dont know if Im convinced the new pump is bad or not, or if I need higher voltage to the pump. Is this just a problem with the thermostat button do you think? I opened the casing again and it had a lot of corrosion within. Articles and resources for swimming pool owners and DIYers. GFCIs are sensitive, but for a reason. It is so poorly designed and the helper handle is basically useless because it bumps into the outlet flow tube and the jandy. Intermittently meaning it could run for days then trip, I could reset the breaker and have it trip again within a few hours, or it could run for days. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. Grids not aligned properly, thus not pushed fully up into manifold A click on the outlet you say? If the meter reads zero, and stays at zero the capacitor is bad. Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. The repair for such an issue is to remove the 6 screws around the lid (dont lose the nuts), and pull the handle to lift the key assembly out of the valve body, where you can inspect the gasket, in the area of the backwash port. If I leave it plugged in then it stays hot, but if I unplug it then it cools off and itll work till it overheats again. So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. Tim, all I can think of is maybe the pump is not self-priming pump? *. Hi Mary, flocculents usually produce a fluffy precipitate that is vacuumed to waste, because it clogs ups the filter. (GFI 240V 20amp) A local electric motor shop should have them, or easy to find online. https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual the first pdf link is the older model H150, the second .pdf link is the newer H150 models, altho it may not make a difference. The Inspect Cell LED (only) flashes or stays on when: The Check Salt & Inspect Cell LEDs flash together when: The Check Salt & Inspect Cell LEDs will stay ON when: Step 1: Check your system to confirm that you have programmed the correct cell size. Any thoughts? Hi Rachel, Im guessing a Hayward Perflex DE filter? Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell - http://bit.ly/2TPpK5IStabilizer - http://bit.ly/3aCeEa7SUBSCRIBE for FREE swimming pool care and maintenance videos every week: http://bit.ly/SubscribeINYO ****VISIT our blog for weekly swimming pool tips, tricks, and more! I presume Ill be looking at buying a new pump next year. However, when I check the connection at the wired, there is definetly juice there. Now it wont flip back on but it is still raining hard. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. We have a sand filter and no pressure gage. If they wont or cant fix it, call a electric motor repair shop to visit, or pull the pump and take it to them for service, or attempt the (easy) repair yourself. Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Had a ball stuck under the skimmer basket, pump got hot and now will not turn back on. Also check other wires in the back of the motor. It's the same as an aquarite with a T-5 cell. Hi Carl, check for an air leak in front of the pump on the suction manifold, or around the pump lid, or on around the threads of the fitting that screws into the pump. If the filter multiport was recently re plumbed, be sure that the pipe from the pump goes into the valve port labeled PUMP, and the pipe to the pool is connected to the valve port labeled RETURN. If all is well then 99% sure it would be the capacitor, weak and needs replacement. Appreciate any help. I have a thermal switch on it,thank goodness or the motor would probably be fried. Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. Remove the bracket and inspect for bulging, cracking, or burnt marks on the end. "
Old bronze pool pumps, like Sta-Rite and Anthony, that use Key Shaft motors with stub shafts need to be shimmed properly. "@type": "Organization",
Since the pool is still being finished, the lines going to and from the pool are not installed yet so wanted to put water in there to test. Step 4: If none of the previous steps solved the problem, replace your flow switch. Flipped the breakers back on this morning after problem fixed. 3. This morning I decided to open fully all valves while pump was on low and no flow was detected. Step 2: Press Diagnostics button 5 times to display the Instant Salt level. Its linked to an AutoChlor switcher and comes on twice a day but failed to switch on a couple of days ago. I removed it and put the old pump back (20 years old), it works and does not shut down. Last year the cap that you would remove to clean the filter was becoming more and more difficult to remove and get back on and now I cannot get it back on at all. You can consult the flow charts for each model, to compare flow rates among two pumps, with a given (or assumed) level of resistance (feet of head). In most cases, no worries that it will blow-out to leave a leaking pump running. Look for insect infestation. The seal was replaced once on one pump and the entire pump has been replaced the other three times. Any ideas? Motor rate state 4 as a max amps, I dont notice a strange noise and water is flowing normal when running, I dont have a check valve in front of pump so it takes 1 minute to get prime, could you help me with a potential root cause.? This error can result commonly in springtime, after the pump has sat all winter rust can develop between the stator and rotor. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Running at low rpm seems to be fine. Pump is sitting about 3 feet below level of water in pool..maybe a bit more. Wouldnt turn back on for a while even after manually flipping the switch. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. It leaks from the impeler case and is noisey, so assy B is no replacement. I checked that the switches and other electrical components properly tightened down and everything appears normal. The outlet the pump is plugged into, I suppose that is a 240V outlet. The problem lies where the power dies! Using a Slime Bag, attached to the pool return, to act as a secondary filter, would be a solution. If your cell looks like 4A, continue to Step 4. 7. inspect breaker, turn off breaker to pool from house main panel). Hi Rob, there could still have been some sand in the pipes yes, and thats probably the problem. training events, warranty The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. Remove the 6 bolts that hold the seal plate to the pump housing Was running fine. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). Hi Davy, When it comes to troubleshooting Hayward pool heater error codes, theres not too much difference between the problem solving process for other gas-fired heaters, made by Jandy, Pentair or Raypak. Any idea what the next most likely culprit could be? Im not sure what happened. Never had an issue with the other motors we have had. Hi, when my Hayward pool heater is on Im getting a sour odour from the exhaust. If error occurs 10 times during a call for heat the control will go into lockout. If not those, it could also be a short in the motor windings, which would be a major failure, requiring a new motor. Hi Keri, I understand, with Hayward Valves, incl the most common top mounted sand filter valve SP0714T, have the Spider Gasket molded to the underside of the rotor. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. This spray is not usually noticed, unless the pump has been running nearly full-head or full-speed. i removed the filter fingers and cleaned numerous times. Air problems dont usually cause the same loud noise, just the low basket water. Do you have any suggestions? Hey John If it is cycling on/off (motor turning on/off) more rapidly, that would usually indicate loose wires, loose breaker, broken wires (sometimes inside the flexible conduit). Not usually related to a tripped GFI, but I suppose they could be linked. It overheated very badly, even burning the hayward sticker off the pump itself maybe a month ago. What am I doing wrong??? Reconnect the pipes and test it out! Third guess is closed or broken valves, clogged filter, clogged impeller, or other obstruction preventing water flow.